News

What are the components of the Safety Control System?

For mission-critical industrial applications, the UWNTEK UW500s (UWinPAS500s) and UW510s (UWinPAS510s) Safety Control Systems offer high safety, reliability, and adaptability. These systems are individually designed to meet SIL2/SIL3 standards for harsh environments and integrate cutting-edge hardware redundancy, fault tolerance, and inherent safety technologies. Below, we'll explore their components, specifications, and features to further assist you in deploying fail-safe operations.

Safety Control System

Core System Architecture

The Safety Control System consists of three main units:

1. Safety Control Station

The central processing center that executes safety-critical logic.

It utilizes hardware module redundancy and fault tolerance.

Subcomponents:

Safety Control Module

Safe Analog Input (AI) Module

Safe Digital Input (DI) Module

Safe Digital Output (DO) Module

Network Switch Module

Power Supply Module

Matching Terminal Blocks

2. Programming and Monitoring Computer

Configures logic, monitors real-time operation, and diagnoses faults.

Uses multi-domain engineering models for adaptive control. 

3. Network Devices

High-security industrial network switches.

Ensures encrypted data transmission with latency less than 1 millisecond.


Software and Security Technology

Intrinsic safety and active defense: Safety Control System prevents network intrusions through runtime integrity checks.

Multi-domain object modeling: Unifies process, logic, and HMI engineering on a single platform.

Real-time safety operations: Achieve cycle times of less than 100 µs through deterministic scheduling.

High availability: Achieve 99.999% uptime through redundant controllers and networks.


FAQ

Q1: What are the safety certifications for the UW500 and UW510?

A: The UW500 meets the SIL2 (SC2) level according to the IEC61508 standard and is certified for safety applications by TÜV. The UW510 goes a step further, achieving SIL3 (SC3) certification and is approved for use in environments where failure is unavoidable, such as nuclear, chemical, and railway applications.


Q2: What redundancy features ensure system reliability? 

A: The modules feature N+1 redundancy. The network uses a ring topology with automatic switchover (<50 milliseconds). Analog/digital inputs utilize a voting mechanism to cross-validate signals, eliminating single points of failure.


Q3: How scalable are these Safety Control Systems?

A: Both support hierarchical expansion. A single UW500/UW510 control station can handle 512 AI points and 1,024 DIO points. Networked stations can scale up to 16,384 AI points and 32,768 DIO points across 32 nodes, making them ideal for plant-wide safety integration.